Anatomical Movement[edit | edit source]

Hip abduction

Testing position[edit | edit source]

Patient is supine with hips and knees in neutral

Goniometer Placement[edit | edit source]

AXIS LOCATION STATIONARY ARM MOVEMENT ARM
ASIS on measured side directed to opposite ASIS parallel to femur, directed to centre of patella

Expected Findings[edit | edit source]

Expected range of motion is 0- 40 degrees (measured from starting position)[1]

References[edit | edit source]

  1. Norkin CC, White DJ. Measurement of joint motion: a guide to goniometry. FA Davis; 2016 Nov 18.