Goniometry: Wrist Extension
Anatomical Movement
Wrist extension
Testing position
Patient is seated with the shoulder abducted to 90 degrees, elbow flexed to 90 degrees and wrist over the edge of a table or plinth with forearm in pronation.
Goniometer Placement
| AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
|---|---|---|
| over lateral triquetrial bone | parallel with the ulnar | parallel with longitudinal axis of 5th metacarpal |
Expected Findings
Expected range of motion is 0- 70 degrees[1]
References