Goniometry: Wrist Flexion

This article is currently under review and may not be up to date. Please come back soon to see the finished work! (31/10/25)


Anatomical Movement

Wrist flexion

Testing position

Patient is seated with the shoulder abducted to 90 degrees, elbow flexed to 90 degrees, the forearm pronated (palm facing down) and supported on the table. The wrist joint should be positioned over the edge of the table in neutral and the fingers should be relaxed. [1]

Goniometer Placement

AXIS LOCATION STATIONARY ARM MOVEMENT ARM
Dorsal/Volar ApproachDorsal aspect of the wrist, positioned over the capitate


Alternative: Ulnar/Lateral Approach

Ulnar styloid process (lateral aspect of the wrist)

Dorsal/Volar ApproachAligned parallel to the dorsal midline of the forearm, using the lateral epicondyle of the humerus for reference


Alternative: Ulnar/Lateral Approach

Aligned parallel to the lateral midline of the ulna

Dorsal/Volar ApproachAligned parallel to the dorsal midline of the third metacarpal


Alternative: Ulnar/Lateral Approach

Aligned parallel to the longitudinal axis of the fifth metacarpal


[2]


Expected Findings

Expected range of motion is 0- 75 degrees