Timed Up and Go Test (TUG): Difference between revisions
David Csepe (talk | contribs) No edit summary |
David Csepe (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
'''Objective''' | |||
To determine fall risk and measure progress of balance, sit to stand, and walking. | |||
'''Intended Population''' | |||
This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others. | This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others. | ||
'''Method of Use''' | '''Method of Use''' | ||
The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used. | The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used. | ||
''Cut-off time for high risk of falls'': Cut-off times to classify subjects as high risk for falling vary based on the study and | ''Cut-off time for high risk of falls'': Cut-off times to classify subjects as high risk for falling vary based on the study and | ||
participants. By using regression analysis Shumway-Cook used 14 seconds as the cut-off. Thus, if a subject took 14 | |||
| seconds or longer he or she was classified as high-risk for falling.<sup>1</sup><br> | ||
''Materials Needed'': one chair with armrest, stopwatch, tape (to mark 3 meters). | ''Materials Needed'': one chair with armrest, stopwatch, tape (to mark 3 meters). | ||
'''Evidence''' | '''Evidence''' | ||
''Reliability:'' | ''Reliability:'' | ||
''Validity:'' | ''Validity:'' | ||
''Sensitivity and Specificity:'' | ''Sensitivity and Specificity:'' | ||
''Minimally Detectable Change:'' | ''Minimally Detectable Change:'' | ||
'''Links''' | '''Links''' | ||
'''References''' | '''References''' | ||
<span id="1320012004994S" style="display: none"> </span>1. Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the timed up & go test. Phys Ther. 2000;80(9):896-903. | <span id="1320012004994S" style="display: none"> </span>1. Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the timed up & go test. Phys Ther. 2000;80(9):896-903. |
Revision as of 00:05, 31 October 2011
Objective
To determine fall risk and measure progress of balance, sit to stand, and walking.
Intended Population
This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others.
Method of Use
The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used.
Cut-off time for high risk of falls: Cut-off times to classify subjects as high risk for falling vary based on the study and
participants. By using regression analysis Shumway-Cook used 14 seconds as the cut-off. Thus, if a subject took 14
seconds or longer he or she was classified as high-risk for falling.1
Materials Needed: one chair with armrest, stopwatch, tape (to mark 3 meters).
Evidence
Reliability:
Validity:
Sensitivity and Specificity:
Minimally Detectable Change:
Links
References
1. Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the timed up & go test. Phys Ther. 2000;80(9):896-903.