Goniometry: Forearm Supination: Difference between revisions
Claire Knott (talk | contribs) (Created page with "== Anatomical Movement == Elbow flexion == Testing position == Patient is supine or seated with the hand supinated and the arm parallel to the midline of the body == Goniom...") |
Claire Knott (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
== Anatomical Movement == | == Anatomical Movement == | ||
Forearm supination | |||
== Testing position == | == Testing position == | ||
Patient is | Patient is seated with the shoulder adducted by their side, elbow flexed to 90 degrees and forearm in the neutral position to start. | ||
A simple trick is to have the patient hold a pen or pencil for ease of measurement. | |||
== Goniometer Placement == | == Goniometer Placement == | ||
Line 11: | Line 13: | ||
!MOVEMENT ARM | !MOVEMENT ARM | ||
|- | |- | ||
| | |over tip of 3rd digit | ||
|parallel with the humerus | |parallel with the humerus | ||
|parallel | |parallel to volar forearm surface | ||
|} | |} | ||
== Expected Findings == | == Expected Findings == | ||
Expected range of motion is | Expected range of motion is 80 - 90 degrees | ||
== References == | == References == |
Revision as of 12:17, 21 January 2019
Anatomical Movement[edit | edit source]
Forearm supination
Testing position[edit | edit source]
Patient is seated with the shoulder adducted by their side, elbow flexed to 90 degrees and forearm in the neutral position to start.
A simple trick is to have the patient hold a pen or pencil for ease of measurement.
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
over tip of 3rd digit | parallel with the humerus | parallel to volar forearm surface |
Expected Findings[edit | edit source]
Expected range of motion is 80 - 90 degrees