Revision as of 12:34, 1 February 2019
Anatomical Movement[edit | edit source]
Hip abduction
Testing position[edit | edit source]
Patient is supine with hips and knees in neutral rotation
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
ASIS on measured side | directed to opposite ASIS | parallel to femur, directed to centre of patella |
Expected Findings[edit | edit source]
Expected range of motion is 45 degrees (measured from starting position)