Anatomical Movement[edit | edit source]

Hip flexion (with knee flexion)

Testing position[edit | edit source]

Patient is supine with hips and knees in neutral rotation

Goniometer Placement[edit | edit source]

AXIS LOCATION STATIONARY ARM MOVEMENT ARM
femoral greater trochanter parallel to the trunk parallel with longitudinal axis of the femur in line with the lateral femoral condyle

Expected Findings[edit | edit source]

Expected range of motion is 120 degrees