Anatomical Movement[edit | edit source]
Hip flexion (with knee flexion)
Testing position[edit | edit source]
Patient is supine with hips and knees in neutral rotation
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
femoral greater trochanter | parallel to the trunk | parallel with longitudinal axis of the femur in line with the lateral femoral condyle |
Expected Findings[edit | edit source]
Expected range of motion is 0- 120 degrees