Revision as of 11:20, 20 January 2019

Anatomical Movement[edit | edit source]

Shoulder abduction

Testing position[edit | edit source]

Patient is supine with palm facing upwards and wrist in supination.

To start the test arm is to be by the patient's side

Goniometer Placement[edit | edit source]

AXIS LOCATION STATIONARY ARM MOVEMENT ARM
inferior lateral coracoid process parallel with the trunk in line with the mid line of the humerus

Expected Findings[edit | edit source]

Expected range of motion is 90 degrees of pure, glenohumeral joint range, 150 degrees of unrestricted shoulder girdle range.