Anatomical Movement[edit | edit source]
Wrist flexion
Testing position[edit | edit source]
Patient is seated with elbow flexed to 90 degrees and wrist over the edge of a table or plinth with forearm in pronation
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
over lateral triquetral bone | parallel with ulna | parallel with longitudinal axis of 5th metacarpal |
Expected Findings[edit | edit source]
Expected range of motion is 75 degrees