Goniometry: Wrist Ulnar Deviation: Difference between revisions
No edit summary |
Claire Knott (talk | contribs) No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 18: | Line 18: | ||
== Expected Findings == | == Expected Findings == | ||
Expected range of motion is 0- | Expected range of motion is 0- 30 degrees<ref>Norkin CC, White DJ. Measurement of joint motion: a guide to goniometry. FA Davis; 2016 Nov 18.</ref> | ||
== References == | == References == |
Latest revision as of 21:53, 20 February 2019
Anatomical Movement[edit | edit source]
Wrist ulnar deviation
Testing position[edit | edit source]
Patient is seated with elbow flexed to 90 degrees and wrist over the edge of a table or plinth with forearm in pronation
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
capitate | dorsal midline of forearm | parallel with longitudinal axis of 3rd metacarpal |
Expected Findings[edit | edit source]
Expected range of motion is 0- 30 degrees[1]
References[edit | edit source]
- ↑ Norkin CC, White DJ. Measurement of joint motion: a guide to goniometry. FA Davis; 2016 Nov 18.