Suctioning

Be the first to edit this page and have your name permanently included as the original editor, see the editing pages tutorial for help.

Original Editor - Your name will be added here if you created the original content for this page.

Lead Editors  

Introduction[edit | edit source]

Oropharangeal and nasopharangeal suction is a technique intended to stimulate a cough to remove excess secretions and / or aspirate secretions from the airways which cannot be removed by the patient’s spontaneous effort. A cough can be stimulated by the catheter in the pharynx (oropharangeal suction) or it may be necessary to pass the catheter between the vocal cords and into the trachea to stimulate a cough (nasopharangeal suction). The trachea is accessed by insertion of a suction catheter either via nasal passage and pharynx (nasotracheal suction) or via the oral cavity and pharynx (orotracheal suction) using an airway adjunct. Nasotracheal suction may be undertaken directly via the nostril without an airway adjunct. However, in some situations, repeated suction is anticipated and therefore a nasopharyngeal airway should be utilised. Secretions are removed by the application of sub-atmospheric pressure via wall mounted suction apparatus or portable suction unit.

Ref (Adult nasal and Oro guideline NHS)

Best Practice

Nasotracheal and orotracheal suction should only be undertaken when other less invasive techniques have proved unsuccessful, and where the secretions are causing physiological deterioration and / or distress (Pedersen et al., 2008) Indications that the patients may need suctioning include audible secretions in upper airway or noisy crackles, on auscultation, palpable secretions, ineffective or weak coughing, desaturation despite increased oxygen requirements or raised respiratory rate.

Nasotracheal and orotracheal suction should only be performed by staff who, have been trained and deemed competent as per local policy with relevant training and education being included in an in-service training programme. In addition, opportunities should be offered locally to competent practitioners at all levels wishing to maintain their skills in tracheal suction.

Description[edit | edit source]

Introduction

Airway suction via nasopharyngeal and oropharyngeal airways

Oropharyngeal (OPA) and nasopharyngeal airways (NPA) can be used to:

  • restore airway patency by separating the tongue from the posterior pharyngeal wall
  • help maintain adequate oxygenation through providing an avenue for adequate ventilation
  • provide access for the removal of secretions in the upper airway via suctioning.

The insertion of an NPA or OPA is indicated for secretion removal in patients who have evidence of secretions in their upper airway but have an absent cough reflex or an impaired, ineffective cough. This often reflects patients who have an altered conscious state, are weak, or neurologically impaired.

Indications that secretions are present in the upper airway that may be accessible via suction include:

  • audible, upper airway transmitted sounds
  • muffling of a patient’s voice by secretions
  • transmitted sounds on auscultation of the chest wall
  • tactile fremitus
  • moist, rattling cough.

When these signs are present and the patient is unable to clear secretions via a voluntary, stimulated, or assisted cough - or by other means (e.g. physiotherapy techniques), suction may be indicated.

Stimulating a cough

Assist or Rub

Assisted cough manoeuvres

During an assisted cough the physiotherapist applies pressure to the chest wall in synchrony with a patient’s cough in order to increase the PEFR achieved. Two common methods include:

  1. an inwards pressure applied to the lower lateral ribs
  2. an A-P pressure applied to the upper anterior chest wall.

If a patient does not have a strong, effective, spontaneous cough, several methods can be used to try and stimulate a stronger cough. These include a tracheal rub and catheter stimulation in the oropharynx.

1. Tracheal rub

The physiotherapist uses a finger or thumb to rub using blunt pressure across the trachea above the supra-sternal notch. (i.e. a flat finger/thumb is used, not pointed).

2. Catheter stimulation of a cough

A cough can be stimulated by inserting the tip of a catheter (FG 10 or 12) along the outside of the teeth and around in to the back of the oropharynx. As the catheter is passed along the side of the teeth, a block is commonly felt when the catheter comes in contact with the mandible. Rotating the catheter gently will allow the catheter to move off the mandible and in to the back of the oropharynx where a cough may be stimulated and/or secretions suctioned.

Avoid passing the catheter directly over the tongue, as this can stimulate the gag reflex.

If successful, this technique may prevent the need for suctioning via the nasopharynx or with a Guedel airway. It may also provide information on a patient's tolerance of oropharyngeal stimulation (e.g. stimulation of biting reflexes, gag reflexes) which may bias selection of nasopharyngeal or oropharyngeal airway insertion if required.


Oropharyngeal Suction

Oropharyngeal (OPA) or “Guedels” airways

An OPA is a rigid PVC tube that is flanged at the proximal (mouth) end and is shaped to conform to the curvature of the palate. When inserted properly, the flange sits just outside the lips and the tube keeps the patient's tongue extended and prevents it from opposing against the posterior pharynx.

Choosing the correct OPA size

OPAs are made in various sizes. The correct size OPA should track from the corner of the patient's mouth to the angle of the jaw. Insertion of an OPA of incorrect size may push the tongue back toward the pharynx creating an obstruction.

OPA insertion

Suction the oropharynx and inspect it for possible obstructions e.g. food, tumours, and dentition e.g. false teeth. Select a size ten or twelve suction catheter. Lubricate the tip of the catheter and insert the catheter into the OPA prior to insertion into the patient’s oropharynx (this step is optional but can speed up the process). Ensure the catheter moves easily through the OPA orifice and position its tip to protrude just beyond the end of the OPA.

Initially the airway goes in upside down, with the distal end pointing towards the roof of the mouth or sideways. This prevents pushing the tongue back into the oropharynx during insertion. When the airway reaches the back of the throat, rotate it so that the curved part fits over the tongue. Proceed with airway suction. If the gag reflex is stimulated and the patient vomits, be prepared to suction the patient's mouth with a Yankauer, and turn them onto their side if necessary.

Duration of use

When suctioning via an OPA, the OPA is usually removed when the suctioning is complete.

Guide to figures (Pic on suctioning via OPA)

  1. Sizing
  2. Position OPA upside down
  3. Insertion of an OPA - rotation through 180 degrees
  4. Rotation of an OPA - rotation through 180 degrees until positioned in airway
  5. Suction via an OPA

Some variations on the insertion of the airway include:[edit | edit source]

a) inserting the airway with a catheter already insitu

Guide to figures (insertion of OPA with catheter already in situ

  1. Size
  2. Catheter preparation in airway
  3. Insertion
  4. Rotation
  5. Suction via an OPA

b) inserting the airway into the oropharynx on its side rather than upside down, and twisting the airway 90 degrees rather than through 180 degrees. Inserting the airway on its side may prevent trauma to the posterior oropharynx if the airway is inserted forcefully.

Guide to figures (using an oropharynx)

  1. Insertion with airway on its side
  2. Rotation through 90 degrees
  3. Airway insitu ready for suction

Nasopharyngeal airways

Suction via the nasopharynx can be performed with or without the use of a nasopharyngeal airway (NPA). Use of an NPA may be preferable in patients who have evidence of secretion retention, and where the quantity of secretions would require frequent suctioning to be performed.

The NPA is a robust, supple but kink-resistant tube made of soft rubber. They are flanged at the proximal (nasal) end. When properly placed, the tip rests behind the tongue, just above the epiglottis, having separated the soft palate from the posterior wall of the oropharynx. A suction catheter can be passed through the tube and into the posterior pharynx and trachea.

The NPA has some advantages over the OPA, they include:

  • an NPA does not stimulate a patient’s gag reflex
  • an NPA is better tolerated than an OPA in conscious patients
  • an NPA can often be left in situ for longer periods than an OPA
  • even while the NPA is in situ, a patient is still able to speak
  • it can be used when access to the mouth is technically difficult (trismus, convulsions).


Choosing the correct NPA size

NPAs are available in a variety of sizes, with variation in both the internal diameters of the airway, and in length.

Research has validated that when sizing an NPA for a patient:[edit | edit source]

  • the length of the NPA is more critical than its diameter
  • ideal NPA length is best judged by considering the patient’s height and gender
  • estimating NPA length by measuring the distance from the tip of the nose to the tragus of the ear has not been validated in adults. A study in Chinese children found a close association between nares-vocal cord distance and nose tip-earlobe distance, with the ideal NPA length being slightly less than this anthropometric measurement.

Duration of use

There is no clear evidence for the ideal duration of NPA placement. General consensus indicates that if clinically indicated, they can remain in place for up to 24 hours. However, to prevent pressure areas, switching the NPA from one to the other nostril every six to eight hours is recommended. The nose should be inspected regularly for pressure areas around the flange of the NPA.

If a patient requires suctioning relatively infrequently e.g. one to four times a day after physiotherapy treatment, then re-inserting the airway before each suction procedure or performing suction without the NPA may be appropriate.

If the patient has copious pulmonary secretions requiring suction every hour or twice hourly, then inserting an NPA and leaving it in situ is warranted to permit easy access and to minimise trauma to the nasal mucosa from repeated insertion of the suction catheter.

Insertion

Suction the oropharynx and inspect it for obstructions e.g. food, tumours, and dentition e.g. false teeth. Inspect the nose to exclude obvious nasal polyps or septal deviation in either nostril. Determine the length of the NPA to use based on the patient’s gender, height and/or nose-eartip.

Before inserting the NPA, place a large safety pin through the shorter edge of the rubber flange of the NPA. Passing suction catheters through the NPA can exert considerable force. A safety pin aids you in supporting the airway and prevents its migration into the nasopharynx. Do not place the safety pin through the lumen of the tube, which will prevent insertion of suction catheters into the lumen.

Lubricate the outside of the airway with a water soluble/aqueous gel (e.g. KY Jelly). Initially choose the larger nostril that is clear from other tubes (e.g. nasogastric tube). Insert the tip of the NPA into the nostril, then slightly lift the nares up and direct the airway to follow a path along the floor of the nose, parallel to the hard palate. Apply gentle partial rotation to the NPA if resistance is felt during insertion e.g. from opposition against the turbinates. If this does not relieve the resistance / obstruction then withdraw the airway and try the other nostril before selecting a smaller size. Insert the airway until the flange is resting against the nostril. Being able to gently rotate the airway is an indication that the size is correct.

Sequence showing correct insertion of an NPA

Guide to figures

1. Correct insertion of an NPA, lifting the nares to reveal the nasal airway and advancement of the NPA parallel to the nasal floor.

2. Gently rotate the NPA if resistance is felt. It should also rotate easily when correctly placed.

3. NPA in situ.

4. Suction performed via the NPA. Lubricate the catheter prior to insertion.

5. Oxygen can be reapplied while the suction catheter is still in situ - if copious secretions are present, desaturation occurs, or to give the patient a rest during the procedure.


Suction without an NPA

Suction via the nasopharynx can also be performed without the use of a nasopharyngeal airway. This may be preferable in patients who have evidence of secretion retention but where the quantity of secretions may not require frequent suctioning to be performed.

The catheter can be advanced in a similar manner as described above for insertion of a nasopharyngeal airway.

Insertion of a catheter into the nasopharynx involves lifting the nares to reveal the nasal airway and advancing the catheter parallel to the nasal floor.


Considerations for insertion

Process and documentation

Process for inserting and suctioning via an NPA or OPA

Indication
  • Establish need for airway suction.
Contraindication
  • Review the patient's medical history and identify contraindications and/or precautions to the insertion of an NPA or OPA
  • SEEK APPROVAL FROM MEDICAL STAFF PRIOR TO INSERTION / SUCTION VIA NASOPHARYNGEAL OR GUEDEL AIRWAYS.
Explanation
  • Explain the procedure to the patient and family.
  • Explain procedure to patient (even when unconscious).
  • Obtain consent when able.
Infection control
  • Don gloves, gown, and goggles.
Position
  • Position the patient in high supported sitting, with the head supported in a neutral position.
Hyper-oxygenate
  • Hyper-oxygenate the patient if able (e.g. increase mask flow rate or FiO2).
Preparation
  • Prepare for suction procedure
    • Sterile/clean gloves (refer to local hospital policy).
    • Suction catheters.
    • Suction equipment functioning, turned on, 80-200mmHg.
    • Yankauer sucker available.
Insert the airway
  • Insert the NPA or OPA (refer to instructions provided previously).
Assess
  • Look - observe skin colour and respiratory rate.
  • Listen - reassess air entry.
  • Feel – for any improvement in chest wall movement (depth of respiration).
  • Note pulse oximetry.
Suction
  • Two people may be required - one to hold the airway in situ and reassure the patient, while the other person performs the suction procedure.
  • Pass the suction catheter until a strong cough is stimulated. In some cases a cough may not be stimulated. In these cases the catheter may be inserted further until secretions are tapped. However, it is important to remember the risk of laryngospasm.
  • If the carina is felt, withdraw slightly before applying the suction.
  • Suction should not be longer than 15secs. Slowly intermit the suction as you withdraw the catheter.
  • If the patient appears distressed or large amounts of secretions are being suctioned, the catheter can be partially withdrawn but remain inside the pharynx and oxygen reapplied, until the patient has recovered and is ready to continue.
  • If vomiting occurs, be prepared to suction the patient's oropharynx and turn them on their side if necessary.
Hints on suction
  • To minimise the chance of entering the oesophagus, position the patient / ask the patient to tilt the head back.
  • If the patient is noted to swallow during insertion of the catheter it may slip into the oesophagus. In these cases, withdraw the catheter slightly, reposition the patient's head into extension and repeat the procedure. The catheter is usually in the trachea if the patient coughs.
  • If difficulty is encountered with the insertion of the airway:
    • reassess the size of the selected airway
    • try extending the patient's neck and/or a head tilt/chin lift manoeuvre to open a patient’s airway
    • lower the head of the bed and remove any pillows from under the patient’s head.
Documentation
  • Time of insertion.
  • Type and size of airway used.
  • Procedural preparation e.g. use of aqueous lubricant, sterile/clean technique, pre-oxygenation, insertion via left or right nostril.
  • Description of insertion e.g. uncomplicated, epistaxis, difficult insertion, unable to pass NPA via left or right nostril, unable to pass catheter.
  • Results of suction.
  • Instructions for other staff e.g. leave NPA in situ for x hrs before removing.

Precautions, contraindications, and complications of inserting an OPA or NPA

Contraindication
  • Pharyngeal obstruction
  • Acute pulmonary oedema
  • Base of skull fractures (use OPA only, NPA / nasal suction contraindicated)
Precautions
  • Bleeding risk (low platelets, raised INR, raised APTT, coagulopathy, warfarin)
  • Haemodynamic instability
  • Haemoptysis
  • Acute face, neck, or head injury
  • Septal deviation and/or prior nasal surgery
  • Children
  • False teeth
  • Recent oral surgery
Complications
  • Trauma
  • Bleeding
  • Vomiting and aspiration
  • Transient bradycardia
  • Laryngospasm
  • Airway obstruction
  • Intracranial placement
  • Migration of the airway
  • Epistaxis
  • Stimulation of the gag reflex
  • Stimulation of a biting reflex
  • Dental trauma


Indication
[edit | edit source]

add text here relating to the indication for the intervention

Clinical Presentation[edit | edit source]

add text here relating to the clinical presentation of the condition, including pre- and post- intervention assessment measures. 

Key Evidence[edit | edit source]

add text here relating to key evidence with regards to any of the above headings

Resources[edit | edit source]

add appropriate resources here, including text links or content demonstrating the intervention or technique

Case Studies[edit | edit source]

add links to case studies here (case studies should be added on new pages using the case study template)

References[edit | edit source]

References will automatically be added here, see adding references tutorial.