== Definition/Description  ==
== Definition/Description  ==


For a maximal efficiency of joint rotation in the hand, there are some pulleys; the transversal carpal ligament, the palmar aponeurosis and some pulleys along the digits.<br>Those pulleys consist in five annular and 3 cruciform pulleys. [1]
For a maximal efficiency of joint rotation in the hand, there are some pulleys; the transversal carpal ligament, the palmar aponeurosis and some pulleys along the digits. Those pulleys consist of 5 annular and 3 cruciform pulleys.<ref>Kaplan EB. Functional and Surgical Anatomy of the Hand. Philadelphia, JB Lippincott Co, 2nd Ed, 1965</ref> 


== Clinically Relevant Anatomy  ==
== Clinically Relevant Anatomy  ==


The most important one’s are the A2 and the A4 pulleys [2], situated at the palmar side of the digits. The A2 pulley is continuous with the periosteum of the proximal phalanx and the A4 pulley is in the middle of the middle phalanx.  
The most important ones are the A2 and the A4 pulleys<ref>Lin GT, Amadic PC, An KN, et al. Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14:949-956, 1989</ref>, situated at the palmar side of the digits. The A2 pulley is continuous with the periosteum of the proximal phalanx and the A4 pulley is in the middle of the middle phalanx.  


<br>The annular pulleys are optimised for the purpose of flexor tendon positioning and gliding.<br>In the A2 pulley there were identified 3 layers [3]. In the outmost layer is a loosely arranged areolar tissue contain fine capillary network. It’s also continue with the synovial membrane that provides nutrient vascular supplies to the pulley. The middle layer of the pulley is densely arranged with collagen bundles, those are oriented perpendicular to the long axis of the flexor tendon. This optimised the resistance of the pulley.<br>The innermost layer, correspond to the gliding surface of the pulley. It is composed of collagen bundles, oriented parallel with the flexor tendon. That optimised the gliding between the flexor tendon en the pulley. Within this layer, elongated elastin fibrils were regularly positioned within the collagen fiber array [4].  
<br>The annular pulleys are optimised for the purpose of flexor tendon positioning and gliding. In the A2 pulley, there were identified 3 layers<ref>Cohen MJ, Kaplan L. Histology and ultrastructure of the human flexor tendon sheath. J Hand Surg Am 12:25-29, 1987 </ref>. In the outmost layer is a loosely arranged areolar tissue containing a fine capillary network. It’s also continuous with the synovial membrane that provides nutrient vascular supplies to the pulley. The middle layer of the pulley is densely arranged with collagen bundles, those are oriented perpendicular to the long axis of the flexor tendon. This optimised the resistance of the pulley. The innermost layer, corresponds to the gliding surface of the pulley. It is composed of collagen bundles, oriented parallel with the flexor tendon. That optimised the gliding between the flexor tendon en the pulley. Within this layer, elongated elastin fibrils were regularly positioned within the collagen fiber array.<ref>Katzman BM, Klein DM, Garven TC, et al. Anatomy and histology of the A5 pulley. J Hand Surg Am 23:653-657, 1998</ref>  
 
== Epidemiology /Etiology  ==
 
add text here <br>  
 
== Characteristics/Clinical Presentation  ==
 
add text here <br>  
 
== Differential Diagnosis  ==
 
add text here


== Diagnostic Procedures  ==
== Diagnostic Procedures  ==


A fresh pulley injury results in a local swelling, tenderness and pain over the affected area.<br>The main indicator to identify if a total rupture of a pulley has occurred is the appearance of the clinical bowstringing (In this case; when the finger is in flexion, the flexor tendon is taking the shortest line between the top and the base of the finger. Instead of following the phalang). 

Bron 2
This method is very conclusive, but you can only use it with a total rupture of the pulley [29].<br>The most recent study I found about the diagnostic procedure of the pulley, was a comparison between the effectiveness of ultrasonography and MRI (Magnetic Resonance Imaging) scanning.<br>This study showed us that the ultrasonography is a better diagnostic tool than the MRI.<br>Not only because it’s an inexpensive method but also because you can have more precision and a better view with the ultrasonography [5].  
A fresh pulley injury results in local swelling, tenderness, and pain over the affected area. The main indicator to identify if a total rupture of a pulley has occurred is the appearance of the clinical bowstringing (In this case; when the finger is in flexion, the flexor tendon is taking the shortest line between the top and the base of the finger. Instead of following the phalange). 

Bron 2
This method is very conclusive, but you can only use it with a total rupture of the pulley.<ref name=":0">Warme, W. J., Brooks, D. (2000) The Effect of circumferential taping on flexor tendon pulley failure in rock climbers. Am. J. Sports Med. 28(5): 674-678</ref><br>A recent study about the diagnostic procedure of the pulley, was a comparison between the effectiveness of ultrasonography and MRI (Magnetic Resonance Imaging) scanning.<br>This study showed us that the ultrasonography is a better diagnostic tool than the MRI. Not only because it’s an inexpensive method but also because you can have more precision and a better view with the ultrasonography.<ref>Martinoli, C., Bianchi, S., Nebolio, M., Derchi, L. E., Garcia, J. F. (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol. 29. 387-391 </ref>
 
== Outcome Measures  ==
 
add links to outcome measures here (also see [[Outcome Measures|Outcome Measures Database]])  


== Examination  ==
== Examination  ==


There are 3 grades in the pulley injury:<br>Grade III: Complete rupture of the pulley causing bowstring of the tendon. Symptoms are: locally pain at the pulley, heard a PO or CRACK, swelling, pain when squeezing or climbing, pain while finger extension<br>Grade II: Partial rupture of the pulley. Symptoms: locally pain at the pulley, pain while <br>extending finger and while climbing<br>Grade I&nbsp;: Sprain in the finger ligament. Symptoms: Locally pain, pain when squeezing<br>or climbing<br><br>
Pulley injuries can be classified according to 3 grades:
* Grade III: Complete rupture of the pulley causing bowstring of the tendon. Symptoms are: locally pain at the pulley, heard a PO or CRACK, swelling, pain when squeezing or climbing, pain during finger extension
* Grade II: Partial rupture of the pulley. Symptoms: locally pain at the pulley, pain while extending the finger and while climbing
* Grade I: Sprain in the finger ligament. Symptoms: Locally pain, pain when squeezing or climbing


== Medical Management    ==
== Medical Management    ==


Tension of the grafts was evaluated to have an idea of the tension that is recommended in a new graft. The tension of an healthy pulley is between 0,49N and 1,69N. <br>On the bases of those findings we recommend that reconstructed pulley be tensioned to approximately 1N [6].<br>Free extrasynovial tendon grafts are the most commune method currently in use for pulley reconstruction.<br>The A2 and A4 are recommended to be reconstructed using multiple loops of free extrasynovial tendon grafts on the same place were the original digital pulley was [7].<br>The strength of the repaired pulley is correlated with the number of loops in the tendon [8].<br>But recent studies suggest that intersynovial donor tendons may be more efficient as free extrasynovial tendon graft [9]. The intersynovial grafts had less frictions, what gives a better mobility in the digits.<br>An other method report on the use of the dorsal wrist retinaculum for the reconstruction of the annular digital pulleys [10]. About 8 cm. of the retinaculum is necessary for the reconstruction of each digital pulley. It is recommended that the under surface of the extensor retinaculum is orientated toward the tendon for a better gliding. An independent biomechanical assessment of this pulley reconstruction concluded that this method gives a limitation in the mechanical effectiveness.<br>The ever present Rim, is a tendon weave technique that is based on the remnant of the ruptured pulley. <br>The advantage of this technique is that the long pulley structure retains the flexor tendon in close proximity to the bone. It’s a very efficient technique but it’s also shown to be one of the weakest pulley reconstruction methods [11].<br>
The tension of the grafts was evaluated to have an idea of the tension that is recommended in a new graft. The tension of a healthy pulley is between 0,49N and 1,69N. <br>On the bases of those findings, it is recommended that reconstructed pulley be tensioned to approximately 1N<ref>Seiler JG, Uchiyama S, Ellis F, et al. Reconstruction of the flexor pulley. the effect of tension and source of the graft in an in vitro dog model. J Bone Joint Surg Am 80:699-703, 1998 </ref>.


== Physical Therapy Management    ==
<br>Free extrasynovial tendon grafts are the most common method currently in use for pulley reconstruction.  The A2 and A4 are recommended to be reconstructed using multiple loops of free extrasynovial tendon grafts in the same place where the original digital pulley was<ref>Bunnell S. Repair of tendons in the fingers and descriptions of two new instruments. Surg Gynecol Obstet 26:103-110, 1918 </ref>.  The strength of the repaired pulley is correlated with the number of loops in the tendon<ref>Widstrom CJ, Doyle JR, Johnson G. A mechanical study of the effectiveness of 6 digital pulley reconstruction techniques. Part 2. Strength of individual reconstructions. J Hand Surg Am 4:826-829,1989</ref>.  However, recent studies suggest that intersynovial donor tendons may be more efficient as free extrasynovial tendon graft<ref>Nishida J, Amadio PC, Bettinger PC, et al. Excursion properties of tendon graft sources. interaction between tendon and A2 pulley. J Hand Surg Am 23:274-278, 1998 </ref>. The intersynovial grafts had less frictions, what gives a better mobility in the digits.


Rohrbough indicates that there remains some disagreement between researchers as to the treatment of pulley tears [15].  
<br>Another method reports on the use of the dorsal wrist retinaculum for the reconstruction of the annular digital pulleys<ref>Lister GD. Reconstruction of pulleys employing extensor retinaculum. J Hand Surg Am 4:461-464, 1979 </ref>. About 8 cm. of the retinaculum is necessary for the reconstruction of each digital pulley. It is recommended that the undersurface of the extensor retinaculum is orientated toward the tendon for better gliding. An independent biomechanical assessment of this pulley reconstruction concluded that this method gives a limitation in mechanical effectiveness.  The ever-present Rim, is a tendon weave technique that is based on the remnant of the ruptured pulley. The advantage of this technique is that the long pulley structure retains the flexor tendon in close proximity to the bone. It is a very efficient technique but has also been shown to be one of the weakest pulley reconstruction methods<ref>Kleinert HE, Bennett JB. Digital pulley reconstruction employing the always present rim of the other previous pulley. J Hand Surg Am 3:297-298, 1978 </ref>.<br>


Stretching is recognized as an important promoter of formation of strong compacted scar tissue[16]. Stretching involves pulling the finger in the varus direction, effectively hyper extending the metacarpophlangeal joint and PIP joint [17].
== Physical Therapy Management    ==


An alternative therapy such a squeezing a ball may be useful. Such therapy is useful in promoting healing in the injury, it does not prevent atrophy of other healthy tissues [14].  
Rohrbough indicates that there remains some disagreement between researchers as to the treatment of pulley tears.<ref>Rohrbough, J. T., Mudge, M. K., Schilling, R. C. (2000) Overuse injuries in the elite rock climber. Med. Sci Sports Exerc. 32(8): 1369-1372 </ref>.  Stretching is recognized as an important promoter of the formation of strong compacted scar tissue<ref>R. S., Raya, M. A. (2001) Manual Modalities. in: Gonzalez, E. G., Myers, S. J., Edelstein, J. E., Lieberman, J. S., Downey, J. A. Physiological basis of rehabilitation medicine. 3rd ed. Butterworth Heinemann </ref>. Stretching involves pulling the finger in the varus direction, effectively hyperextending the metacarpophalangeal joint and PIP joint<ref>Gresham, N. (1996) High performance: warming up. High. 166: 14-15 </ref>.  An alternative therapy such a squeezing a ball may be useful. Such therapy is useful in promoting healing in the injury, it does not prevent atrophy of other healthy tissues.  


Minor A2 pulley injuries or partial tears with no evidence of bowstringing can be treated with either firm circumferential taping for 2 to 3 months to permit healing [13].<br>The effectiveness of pulley taping was tested [18]. The effect was maximized (10% of bowstringing force) when the tape is positioned near the distal end of the proximal phalanx. The tape absorbed progressively less bowstringing force as the force produced at the fingertip increased [18]. Non stretch, zinc oxide tape of 1.3 cm width was used [13]. This result has two implications. Firstly, taping is likely to be most effective during the earlier stages of rehabilitation when the forces produced by the fingers are lower. Secondly, taping is unlikely to prevent pulley injuries, as these are likely to occur when forces on the pulley are maximal [19].<br>  
Minor A2 pulley injuries or partial tears with no evidence of bowstringing can be treated with either firm circumferential taping for 2 to 3 months to permit healing<ref name=":1">Hand Injuries in Rock Climbing. Reaching the Right Treatment Peter J. L. Jebson, MD; Curtis M. Steyers, MD The Physician and Sportsmedicine – Vol 25: No5, May 1997 </ref>The effectiveness of pulley taping was tested and the effect was maximized (10% of bowstringing force) when the tape is positioned near the distal end of the proximal phalanx. The tape absorbed progressively less bowstringing force as the force produced at the fingertip increased<ref>Schweizer, A. (2000) Biomechanical effectiveness of taping the A2 pulley in rock climbers. J. Hand Surg. 25B. 102-107 </ref>; non-stretch, zinc oxide tape of 1.3 cm width was used<ref name=":1" />. This result has two implications. Firstly, taping is likely to be most effective during the earlier stages of rehabilitation when the forces produced by the fingers are lower. Secondly, taping is unlikely to prevent pulley injuries, as these are likely to occur when forces on the pulley are maximal<ref name=":0" />.


== Key Research  ==
== Key Research  ==
Line 58: Line 45:
Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An􏰀 Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008  
Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An􏰀 Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008  


Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD



<br>  
Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD
 
== Resources ==
Bron 1: http://www.orthobullets.com/hand/6004/flexor-pulley-system<br>Bron 2: http://edgar.brand.edgar-online.com/EFX_dll/EDGARpro.dll?FetchFilingHTML1?ID=5479903&amp;SessionID=cg7xWq-zAf69x47<br>


== References  ==
== References  ==
 
 <references />
<br>
 
Kaplan EB: Functional and Surgical Anatomy of the Hand. Philadelphia, JB Lippincott Co, 2nd Ed, 1965<br>Lin GT, Amadic PC, An KN, et al: Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14:949-956, 1989
 
<br>Cohen MJ, Kaplan L: Histology and ultrastructure of the human flexor tendon sheath. J Hand Surg Am 12:25-29, 1987 Level of evidence C<br>
 
Katzman BM, Klein DM, Garven TC, et al: Anatomy and histology of the A5 pulley. J Hand Surg Am 23:653-657, 1998 <br>
 
Martinoli, C., Bianchi, S., Nebolio, M., Derchi, L. E., Garcia, J. F. (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol. 29: 387-391 Level of evidence: 2<br>
 
Seiler JG, Uchiyama S, Ellis F, et al: Reconstruction of the flexor pulley. the effect of tension and source of the graft in an in vitro dog model. J Bone Joint Surg Am 80:699-703, 1998 Level of evidence: A2<br>
 
Bunnell S: Repair of tendons in the fingers and descriptions of two new instruments. Surg Gynecol Obstet 26:103-110, 1918 Level of evidence: B<br>
 
Widstrom CJ, Doyle JR, Johnson G: A mechanical study of the effectiveness of 6 digital pulley reconstruction techniques: Part 2. Strength of individual reconstructions. J Hand Surg Am 4:826-829,1989 Level of evidence: B<br>
 
Nishida J, Amadio PC, Bettinger PC, et al: Excursion properties of tendon graft sources: interaction between tendon and A2 pulley. J Hand Surg Am 23:274-278, 1998 Level of evidence: C<br>
 
Lister GD: Reconstruction of pulleys employing extensor retinaculum. J Hand Surg Am 4:461-464, 1979 Level of evidence: C<br>
 
Kleinert HE, Bennett JB: Digital pulley reconstruction employing the always present rim of the other previous pulley. J
 
Hand Surg Am 3:297-298, 1978 Level of evidence:C<br>
 
Bowstring injury of the flexor tendon pulley system: MR imaging. Parellada JA, Balkissoon AR, Hayes CW, Conway WF. Source Department of Radiology, Medical College of Virginia, Virginia Commonwealth University, Richmond 23298,USA.31 Level of evidence: B<br>
 
Hand Injuries in Rock Climbing: Reaching the Right Treatment Peter J. L. Jebson, MD; Curtis M. Steyers, MD THE PHYSICIAN AND SPORTSMEDICINE - VOL 25 - NO. 5 - MAY 97 Level of evidence B<br>A2 PULLEY INJURIES REVIEW RE-POSTED, TUESDAY, 4 MAY 2010 Dave macleod<br>
 
Rohrbough, J. T., Mudge, M. K., Schilling, R. C. (2000) Overuse injuries in the elite rock climber. Med. Sci Sports Exerc. 32(8): 1369-1372 Level of evidence B<br>
 
Gailey, R. S., Raya, M. A. (2001) Manual Modalities. in: Gonzalez, E. G., Myers, S. J., Edelstein, J. E., Lieberman, J. S., Downey, J. A. Physiological basis of rehabilitation medicine. 3rd ed. Butterworth Heinemann Level of evidence: <br>Gresham, N. (1996) High performance: warming up. High. 166: 14-15 Level of evidence D<br>Schweizer, A. (2000) Biomechanical effectiveness of taping the A2 pulley in rock climbers. J. Hand Surg. 25B: 102-107 Level of evidence<br>
 
Warme, W. J., Brooks, D. (2000) The Effect of circumferential taping on flexor tendon pulley failure in rock climbers. Am. J. Sports Med. 28(5): 674-678 Level of evidence:


<br>  
<br>  
Digital Flexor Sheath: Repair and Reconstruction of the Annular Pulleys and Membranous Sheath
Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An􏰀 Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008
Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD
<br>Bron 1: http://www.orthobullets.com/hand/6004/flexor-pulley-system<br>Bron 2: http://edgar.brand.edgar-online.com/EFX_dll/EDGARpro.dll?FetchFilingHTML1?ID=5479903&amp;SessionID=cg7xWq-zAf69x47


[[Category:Vrije Universiteit Brussel Project|Template:VUB]]
[[Category:Vrije Universiteit Brussel Project|Template:VUB]]
[[Category:Anatomy]]
[[Category:Hand]]
[[Category:Hand - Anatomy]]

Revision as of 13:47, 30 November 2019

Definition/Description[edit | edit source]

For a maximal efficiency of joint rotation in the hand, there are some pulleys; the transversal carpal ligament, the palmar aponeurosis and some pulleys along the digits. Those pulleys consist of 5 annular and 3 cruciform pulleys.[1]

Clinically Relevant Anatomy[edit | edit source]

The most important ones are the A2 and the A4 pulleys[2], situated at the palmar side of the digits. The A2 pulley is continuous with the periosteum of the proximal phalanx and the A4 pulley is in the middle of the middle phalanx.


The annular pulleys are optimised for the purpose of flexor tendon positioning and gliding. In the A2 pulley, there were identified 3 layers[3]. In the outmost layer is a loosely arranged areolar tissue containing a fine capillary network. It’s also continuous with the synovial membrane that provides nutrient vascular supplies to the pulley. The middle layer of the pulley is densely arranged with collagen bundles, those are oriented perpendicular to the long axis of the flexor tendon. This optimised the resistance of the pulley. The innermost layer, corresponds to the gliding surface of the pulley. It is composed of collagen bundles, oriented parallel with the flexor tendon. That optimised the gliding between the flexor tendon en the pulley. Within this layer, elongated elastin fibrils were regularly positioned within the collagen fiber array.[4]

Diagnostic Procedures[edit | edit source]

A fresh pulley injury results in local swelling, tenderness, and pain over the affected area. The main indicator to identify if a total rupture of a pulley has occurred is the appearance of the clinical bowstringing (In this case; when the finger is in flexion, the flexor tendon is taking the shortest line between the top and the base of the finger. Instead of following the phalange). 

Bron 2
This method is very conclusive, but you can only use it with a total rupture of the pulley.[5]
A recent study about the diagnostic procedure of the pulley, was a comparison between the effectiveness of ultrasonography and MRI (Magnetic Resonance Imaging) scanning.
This study showed us that the ultrasonography is a better diagnostic tool than the MRI. Not only because it’s an inexpensive method but also because you can have more precision and a better view with the ultrasonography.[6]

Examination[edit | edit source]

Pulley injuries can be classified according to 3 grades:

  • Grade III: Complete rupture of the pulley causing bowstring of the tendon. Symptoms are: locally pain at the pulley, heard a PO or CRACK, swelling, pain when squeezing or climbing, pain during finger extension
  • Grade II: Partial rupture of the pulley. Symptoms: locally pain at the pulley, pain while extending the finger and while climbing
  • Grade I: Sprain in the finger ligament. Symptoms: Locally pain, pain when squeezing or climbing

Medical Management[edit | edit source]

The tension of the grafts was evaluated to have an idea of the tension that is recommended in a new graft. The tension of a healthy pulley is between 0,49N and 1,69N.
On the bases of those findings, it is recommended that reconstructed pulley be tensioned to approximately 1N[7].


Free extrasynovial tendon grafts are the most common method currently in use for pulley reconstruction. The A2 and A4 are recommended to be reconstructed using multiple loops of free extrasynovial tendon grafts in the same place where the original digital pulley was[8]. The strength of the repaired pulley is correlated with the number of loops in the tendon[9]. However, recent studies suggest that intersynovial donor tendons may be more efficient as free extrasynovial tendon graft[10]. The intersynovial grafts had less frictions, what gives a better mobility in the digits.


Another method reports on the use of the dorsal wrist retinaculum for the reconstruction of the annular digital pulleys[11]. About 8 cm. of the retinaculum is necessary for the reconstruction of each digital pulley. It is recommended that the undersurface of the extensor retinaculum is orientated toward the tendon for better gliding. An independent biomechanical assessment of this pulley reconstruction concluded that this method gives a limitation in mechanical effectiveness. The ever-present Rim, is a tendon weave technique that is based on the remnant of the ruptured pulley. The advantage of this technique is that the long pulley structure retains the flexor tendon in close proximity to the bone. It is a very efficient technique but has also been shown to be one of the weakest pulley reconstruction methods[12].

Physical Therapy Management[edit | edit source]

Rohrbough indicates that there remains some disagreement between researchers as to the treatment of pulley tears.[13]. Stretching is recognized as an important promoter of the formation of strong compacted scar tissue[14]. Stretching involves pulling the finger in the varus direction, effectively hyperextending the metacarpophalangeal joint and PIP joint[15]. An alternative therapy such a squeezing a ball may be useful. Such therapy is useful in promoting healing in the injury, it does not prevent atrophy of other healthy tissues.

Minor A2 pulley injuries or partial tears with no evidence of bowstringing can be treated with either firm circumferential taping for 2 to 3 months to permit healing[16]. The effectiveness of pulley taping was tested and the effect was maximized (10% of bowstringing force) when the tape is positioned near the distal end of the proximal phalanx. The tape absorbed progressively less bowstringing force as the force produced at the fingertip increased[17]; non-stretch, zinc oxide tape of 1.3 cm width was used[16]. This result has two implications. Firstly, taping is likely to be most effective during the earlier stages of rehabilitation when the forces produced by the fingers are lower. Secondly, taping is unlikely to prevent pulley injuries, as these are likely to occur when forces on the pulley are maximal[5].

Key Research[edit | edit source]

Digital Flexor Sheath: Repair and Reconstruction of the Annular Pulleys and Membranous Sheath

Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An􏰀 Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008

Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD

Resources[edit | edit source]

Bron 1: http://www.orthobullets.com/hand/6004/flexor-pulley-system
Bron 2: http://edgar.brand.edgar-online.com/EFX_dll/EDGARpro.dll?FetchFilingHTML1?ID=5479903&SessionID=cg7xWq-zAf69x47

References[edit | edit source]

 

  1. Kaplan EB. Functional and Surgical Anatomy of the Hand. Philadelphia, JB Lippincott Co, 2nd Ed, 1965
  2. Lin GT, Amadic PC, An KN, et al. Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14:949-956, 1989
  3. Cohen MJ, Kaplan L. Histology and ultrastructure of the human flexor tendon sheath. J Hand Surg Am 12:25-29, 1987 
  4. Katzman BM, Klein DM, Garven TC, et al. Anatomy and histology of the A5 pulley. J Hand Surg Am 23:653-657, 1998
  5. 5.0 5.1 Warme, W. J., Brooks, D. (2000) The Effect of circumferential taping on flexor tendon pulley failure in rock climbers. Am. J. Sports Med. 28(5): 674-678
  6. Martinoli, C., Bianchi, S., Nebolio, M., Derchi, L. E., Garcia, J. F. (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol. 29. 387-391 
  7. Seiler JG, Uchiyama S, Ellis F, et al. Reconstruction of the flexor pulley. the effect of tension and source of the graft in an in vitro dog model. J Bone Joint Surg Am 80:699-703, 1998 
  8. Bunnell S. Repair of tendons in the fingers and descriptions of two new instruments. Surg Gynecol Obstet 26:103-110, 1918 
  9. Widstrom CJ, Doyle JR, Johnson G. A mechanical study of the effectiveness of 6 digital pulley reconstruction techniques. Part 2. Strength of individual reconstructions. J Hand Surg Am 4:826-829,1989
  10. Nishida J, Amadio PC, Bettinger PC, et al. Excursion properties of tendon graft sources. interaction between tendon and A2 pulley. J Hand Surg Am 23:274-278, 1998 
  11. Lister GD. Reconstruction of pulleys employing extensor retinaculum. J Hand Surg Am 4:461-464, 1979 
  12. Kleinert HE, Bennett JB. Digital pulley reconstruction employing the always present rim of the other previous pulley. J Hand Surg Am 3:297-298, 1978 
  13. Rohrbough, J. T., Mudge, M. K., Schilling, R. C. (2000) Overuse injuries in the elite rock climber. Med. Sci Sports Exerc. 32(8): 1369-1372 
  14. R. S., Raya, M. A. (2001) Manual Modalities. in: Gonzalez, E. G., Myers, S. J., Edelstein, J. E., Lieberman, J. S., Downey, J. A. Physiological basis of rehabilitation medicine. 3rd ed. Butterworth Heinemann 
  15. Gresham, N. (1996) High performance: warming up. High. 166: 14-15 
  16. 16.0 16.1 Hand Injuries in Rock Climbing. Reaching the Right Treatment Peter J. L. Jebson, MD; Curtis M. Steyers, MD The Physician and Sportsmedicine – Vol 25: No5, May 1997 
  17. Schweizer, A. (2000) Biomechanical effectiveness of taping the A2 pulley in rock climbers. J. Hand Surg. 25B. 102-107