Incentive Spirometry: Difference between revisions

No edit summary
No edit summary
Line 13: Line 13:
# Patient should be in a relaxed position suitable for deep breathing (e.g. sitting upright in a chair or side lying if extra volume is required in one lung due to ventilation perfusion matching).  
# Patient should be in a relaxed position suitable for deep breathing (e.g. sitting upright in a chair or side lying if extra volume is required in one lung due to ventilation perfusion matching).  
#. Patient creates a tight seal around the mouthpiece and inhales deeply and slowly. The patient watches the flow meter for visual feedback. If possible the patient sustains the inhalation to create an end-inspiratory hold. Ideally the inhalation is sustained for 4-5 seconds.  
#. Patient creates a tight seal around the mouthpiece and inhales deeply and slowly. The patient watches the flow meter for visual feedback. If possible the patient sustains the inhalation to create an end-inspiratory hold. Ideally the inhalation is sustained for 4-5 seconds.  
#&nbsp;Patient relaxes seal around mouthpiece and exhales; normal breathing is resumed with relaxed shoulder girdle. <br><br>
#&nbsp;Patient relaxes seal around mouthpiece and exhales; normal breathing is resumed with relaxed shoulder girdle.  
 
Further pointers:


*Advise patient to take approximately ten incentive spirometry breaths per waking hour (use clinical reasoning to prescribe using Frequency, Intensity, Time and Type principles).  
*Advise patient to take approximately ten incentive spirometry breaths per waking hour (use clinical reasoning to prescribe using Frequency, Intensity, Time and Type principles).  
Line 21: Line 23:
*The device is not suitable for people with severe dyspnoea.
*The device is not suitable for people with severe dyspnoea.


<br>  
The video below explains more on the use of the incentive spirometer<br>  


{{#ev:youtube|-O-Zawtb32o|300}}<ref>My Doctor - Kaiser Permanente. Learn to Use an Incentive Spiromete. Available from: https://www.youtube.com/watch?v=-O-Zawtb32o [last accessed 2/23/2016]</ref>  
{{#ev:youtube|-O-Zawtb32o|300}}<ref>My Doctor - Kaiser Permanente. Learn to Use an Incentive Spiromete. Available from: https://www.youtube.com/watch?v=-O-Zawtb32o [last accessed 2/23/2016]</ref>  
Line 29: Line 31:
== Indications<ref>Restrepo RD, Wettstein R, Wittnebel L, Tracy M. Incentive Spirometry: 2011, AARC Clinical Practice Guideline. Respiratory Care 2011; 56:10 p1600-1604.</ref>  ==
== Indications<ref>Restrepo RD, Wettstein R, Wittnebel L, Tracy M. Incentive Spirometry: 2011, AARC Clinical Practice Guideline. Respiratory Care 2011; 56:10 p1600-1604.</ref>  ==


- Pre-operative screening of patients at risk of post-operative complications to obtain a baseline of their inspiratory flow and volume<br>- Presence of pulmonary atelectasis or conditions predisposing to atelectasis<br>- Abdominal or thoracic surgery<br>- Prolonged bed rest<br>- Surgery in patients with COPD<br>- Lack of pain control<br>- Restrictive lung disease associated with a dysfunctional diaphragm or involving respiratory musculature<br>- Patients with inspiratory capacity less than 2.5 litres<br>- Patients with neuromuscular disease or spinal cord injury<br>  
*Pre-operative screening of patients at risk of post-operative complications to obtain a baseline of their inspiratory flow and volume
*Presence of pulmonary atelectasis or conditions predisposing to atelectasis
*Abdominal or thoracic surgery
*Prolonged bed rest
*Surgery in patients with COPD
*Lack of pain control
*Restrictive lung disease associated with a dysfunctional diaphragm or involving respiratory musculature
*Patients with inspiratory capacity less than 2.5 litres
*Patients with neuromuscular disease or spinal cord injury<br>


== Contraindications or Precautions  ==
== Contraindications or Precautions  ==


- Patients who cannot use the device appropriately or require supervision at all times<br>- Patients who are non-compliant or do not understand or demonstrate proper use of the device<br>- Very young patients or paediatrics with developmental delay<br>- Hyperventilation <br>- Hypoxaemia secondary to interruption of oxygen therapy<br>- Fatigue<br>- Pain<br>  
*Patients who cannot use the device appropriately or require supervision at all times
*Patients who are non-compliant or do not understand or demonstrate proper use of the device
*Very young patients or paediatrics with developmental delay
*Hyperventilation  
*Hypoxaemia secondary to interruption of oxygen therapy
*Fatigue
*Pain<br>


== References  ==
== References  ==


<references />
<references />

Revision as of 14:01, 23 February 2016

Guideline on appropriate use[edit | edit source]

The purpose of incentive spirometry is to facilitate a sustained slow deep breath. The device gives the individual visual feedback regarding flow and volume. The device can prevent and reverse atelectasis when used appropriately and regularly.[1]


  1. Therapist demonstrates using a separate device and provides information sheet regarding technique, prescription of use and cleaning advice based on manufacturers instructions.
  2.  Patient should be in a relaxed position suitable for deep breathing (e.g. sitting upright in a chair or side lying if extra volume is required in one lung due to ventilation perfusion matching).
  3. . Patient creates a tight seal around the mouthpiece and inhales deeply and slowly. The patient watches the flow meter for visual feedback. If possible the patient sustains the inhalation to create an end-inspiratory hold. Ideally the inhalation is sustained for 4-5 seconds.
  4.  Patient relaxes seal around mouthpiece and exhales; normal breathing is resumed with relaxed shoulder girdle.

Further pointers:

  • Advise patient to take approximately ten incentive spirometry breaths per waking hour (use clinical reasoning to prescribe using Frequency, Intensity, Time and Type principles).
  • Patients with an oxygen requirement can use device with a nasal cannulae or a device, which entrains oxygen.
  • Deep breathing offers a similar effect. However, using an incentive device as feedback may create greater inhaled volumes, greater control of flow and more motivation to participate in therapy.
  • The device can be used with paediatrics and individuals with learning difficulties.
  • The device is not suitable for people with severe dyspnoea.

The video below explains more on the use of the incentive spirometer

[2]


Indications[3][edit | edit source]

  • Pre-operative screening of patients at risk of post-operative complications to obtain a baseline of their inspiratory flow and volume
  • Presence of pulmonary atelectasis or conditions predisposing to atelectasis
  • Abdominal or thoracic surgery
  • Prolonged bed rest
  • Surgery in patients with COPD
  • Lack of pain control
  • Restrictive lung disease associated with a dysfunctional diaphragm or involving respiratory musculature
  • Patients with inspiratory capacity less than 2.5 litres
  • Patients with neuromuscular disease or spinal cord injury

Contraindications or Precautions[edit | edit source]

  • Patients who cannot use the device appropriately or require supervision at all times
  • Patients who are non-compliant or do not understand or demonstrate proper use of the device
  • Very young patients or paediatrics with developmental delay
  • Hyperventilation
  • Hypoxaemia secondary to interruption of oxygen therapy
  • Fatigue
  • Pain

References[edit | edit source]

  1. Hough A, Physiotherapy in Respiratory and Cardiac Care: an evidence based approach. 4th Edition. Cengage Learning, 2014. p186-189.
  2. My Doctor - Kaiser Permanente. Learn to Use an Incentive Spiromete. Available from: https://www.youtube.com/watch?v=-O-Zawtb32o [last accessed 2/23/2016]
  3. Restrepo RD, Wettstein R, Wittnebel L, Tracy M. Incentive Spirometry: 2011, AARC Clinical Practice Guideline. Respiratory Care 2011; 56:10 p1600-1604.