<div>The cycles of positive and negative pressure aids in improving circulation. The volume of an elastic vessel can be increased by the application of a vacuum force on its outer wall<ref name="nave">Nave CR, Nave BC, eds. Physcs for the Health Sciences. Philadelphia, Pa: WB Saunders CO; 1975:73-75.</ref> In the negative pressure phase of VCT , just such a force is exerted on the extremities and its vessels.In the positive pressure phase, the venous drainage is facilitated.Thus the alteration of positive and negative pressure facilitates increased arterial and capillary circulation and better venous drainage.<br></div><div><br></div> | <div>The cycles of positive and negative pressure aids in improving circulation. The volume of an elastic vessel can be increased by the application of a vacuum force on its outer wall<ref name="nave">Nave CR, Nave BC, eds. Physcs for the Health Sciences. Philadelphia, Pa: WB Saunders CO; 1975:73-75.</ref> In the negative pressure phase of VCT , just such a force is exerted on the extremities and its vessels.In the positive pressure phase, the venous drainage is facilitated.Thus the alteration of positive and negative pressure facilitates increased arterial and capillary circulation and better venous drainage.<br></div><div><br></div> | ||
== Technique of Application == | == Technique of Application == | ||
<div>The individuals’s extremity will be placed inside the plexiglass chamber of the vacuum compression device up to mid thigh without clothing. The rubber cuff of appropriate size for the individual was selected based of mid thigh/mid arm circumference to ensure snug fit. The parameters to be set at negative pressure of – 0.10 bar (-75 mmHg) for 60 seconds and positive pressure of 0.05 bar (38.5 mmHg) for 30 seconds as suggested by Akbari et al (2007)<ref name="akbari" /> (For diabetic ulcer healing) <br></div><div> </div><div> </div><div> [[Image:Vct-2.jpg]]<br></div><div><br></div> | <div>The individuals’s extremity will be placed inside the plexiglass chamber of the vacuum compression device up to mid thigh without clothing. The rubber cuff of appropriate size for the individual was selected based of mid thigh/mid arm circumference to ensure snug fit. The parameters to be set at negative pressure of – 0.10 bar (-75 mmHg) for 60 seconds and positive pressure of 0.05 bar (38.5 mmHg) for 30 seconds as suggested by Akbari et al (2007)<ref name="akbari" /> (For diabetic ulcer healing) <br></div><div> </div><div> </div><div> [[Image:Vct-2.jpg]]<br></div><div><br></div> | ||
== Duration == | == Duration == | ||
Literature evidences suggest the therapy for one hour on alterative days for ten sessions . | Literature evidences suggest the therapy for one hour on alterative days for ten sessions . | ||
<br> | <br> | ||
== Instruction == | == Instruction == | ||
The individuals should be instructed that they will feel sense of pull during negative pressure phase and sense of push during positive pressure phase. Any uncomfortable sensations should be repored immediately. | The individuals should be instructed that they will feel sense of pull during negative pressure phase and sense of push during positive pressure phase. Any uncomfortable sensations should be repored immediately. | ||
== Side effects == | == Side effects == | ||
There may be few temporary side effects like tingling and numbness may occur. | There may be few temporary side effects like tingling and numbness may occur. | ||
<div></div> <div></div> | <div></div> <div></div> | ||
== Recent Related Research (from [http://www.ncbi.nlm.nih.gov/pubmed/ Pubmed]) == | |||
<div class="researchbox"><rss>http://www.ncbi.nlm.nih.gov/entrez/eutils/erss.cgi?rss_guid=18A2e0_HeVtV9k4zNuzvYFSuh5Ck38BCLWW3Wrlll4hWvJ8AtH|charset=UTF-8|short|max=10</rss></div> | |||
== References == | == References == | ||
<references />. <br> | <references />. <br> |
Revision as of 13:42, 17 March 2014
Original Editor - Sheik Abdul Khadir
Top Contributors - Sheik Abdul Khadir, WikiSysop, Kim Jackson and Lucinda hampton
Introduction[edit | edit source]
Device [edit | edit source]
- Vacuum chamber
- Pressure Monitor
- Rubber cuff
- Compressor Unit.
Physiology[edit | edit source]
Technique of Application[edit | edit source]
Duration[edit | edit source]
Literature evidences suggest the therapy for one hour on alterative days for ten sessions .
Instruction[edit | edit source]
The individuals should be instructed that they will feel sense of pull during negative pressure phase and sense of push during positive pressure phase. Any uncomfortable sensations should be repored immediately.
Side effects[edit | edit source]
There may be few temporary side effects like tingling and numbness may occur.
Recent Related Research (from Pubmed)[edit | edit source]
References[edit | edit source]
.